OPTI-FC412 – Ridge vent for cathedral roof

This Cathedral-type roof vent exchanges the air from the attic with the combination of a 3-or 4-fin vent. It is the ideal system for preventing heat and moisture accumulation in the attic that damages the structural integrity of the building and its components. By exchanging air from the space between each roof truss with the air coming from the soffit, the stale air will be directed towards the vent and the introduction of fresh air will maintain the ideal temperature for the attic. There will be an uninterrupted exchange of air. There will be an exchange of air in the attic at a frequency of 418 ft ³/min, thus ventilating an area of 1000 to 1200 sq. ft.

Would you buy this product?

FIND A RETAILER

Advantages

  • Optimizes and evenly regulates the ventilation of the attic
  • Facilitates the evacuation of heat and condensation
  • Preserves the integrity of the attic materials
  • Design adjusts easily to the ridge of roofing, sheet metal or shingles with a professional look
  • Easy to assemble and install
  • Consumer friendly lead times

Documentation

Use

Use

Ventilation is required by the Canadian Building Code. So a Good ventilation means keeping the attic space near the outside temperature to avoid excessive contrasts. With the help of soffits, for example In summer, the chimney effect created by the Optimum ventilator eliminates excess heat from the attic and thus helps maintain the integrity of the asphalt shingles. In winter, you will get a drier attic. So no matter what the season, Optimum Ventilators will help to optimize the comfort of your home!

Specifications

PRODUCT EVACUATION NUMBER OF DEFLECTORS STEEL GAUGE USED MATERIAL
OPTI-FC412 0,09 m² • 144 in.² 4 22 – 24 & 26 Galvanized steel
Part of L’OPTI-FC412 DESCRIPTION
1 – Ventilator A vent has to be calculated at each 20′ of lenght. Not more. For roof exceeding 20′, the distance between ventilators can be reduced. You should also take care of the look once finished.
A B C D
30,4 cm • 12” 50,8 cm • 20” 25,4 cm • 10” 27,9 cm • 11”
2 – Base The adapter connects the ventilator to the insulated duct. An adapter is required for each ventilator. Adapters are insulated, painted and perforated.
3 – Duct Built of 26-gauge steel, interior insulated , painted and perforated every 6″ on the sides, the duct has to be attached to the ridge of the roof. Each section is 48″ long . The 2″ first and last inches has to overlap the section giving you a total lenght of 44″ per section once finished.
N.B. Please specify the slope of the roof.
4 – Cap All parts are, painted and perforated and ready for installation.

Characteristics

The vent is manufactured from galvanized steel followed by a specialized baked paint finish.

Custom model

Custom models are available as special order. *We can manufacture any other size on request.  **Please indicate the slope of the roof and the desired color

Colours

Standard colours available: brown, grey and black. Other colours available as special order (additional fee).

Norms

CSA Certified

The National Building Code requires adequate ventilation of the roof as per the minimum standard of Section 9.19.1 or according to the ACNOR CAN3-A93-M82. 

Warranty

Optimum vents have a limited lifetime warranty against any manufacturing defects that may affect the unit. We can offer this peace of mind to all our customers because all our products are CSA approved. We apply also those same criterias of quality on all custom models. This means that during the time when the owner of the house who installed or had installed the Optimum vent remains at the address of the installation, Ventilation Optimum replace it free for the first five years and thereafter, in proportion to the years of use, against any defect. In such a case, the cost of transportation and installation will be at the customer charge as well as any home repairs. The warranty applies in all cases where the Optimum vent has been installed according to our recommendations and has been free from any abuse, misuse or other circumstances beyond the control of Ventilation Optimum including salty air.
Warranty regarding painting:
The Optimum Roof Ventilator is made of 24 and 26 gauge galvanized steel and is coated with a powder or liquid baked polyester based paint. Optimum Ventilation is proud to offer you a 5 year warranty against corrosion. During this period, Ventilation Optimum will replace the product at the counter upon presentation of the original proof of purchase.
Conditions:
The responsibility of Ventilation Optimum is limited only to the replacement of parts in the workshop. All expenses related to time, travel and home repairs are not covered by this warranty.
Corrosion that does not result from a defect in material or workmanship is not covered by this warranty. Circumstances beyond the control of Ventilation Optimum such as: corrosion caused by industrial fallout, acid rain, accidents, damage, negligence, modification of the product as well as that resulting from improper installation damaging steel, paint scratched by handling, installation or negligence, by an acid environment such as swine farms etc … are excluded from this warranty.
This warranty also excludes damage caused by:
– Infiltration of water due to an improper installation that does not comply with the recommendations and instructions of the manufacturer,
– The infiltration of water and / or condensation due to a building deficiency at the level of the national building code.
– Failure of roof drainage.
– The accumulation of snow covering the vent
– Any domestic paint applications or inappropriate cleaning solutions.
– Bad weather and natural disasters
– Transportation, handling or storage
Tightness of the roof or parts installed by the contractor are not guaranteed as they are out of the control of the manufacturer. It is the roofer’s responsibility to ensure that the base is properly waterproofed using the proper roofing products. The Association of Master Roofers (AMCQ) recommends using the following technique: Metal flanges: The metal flanges of all projections must be coated with a primer embedded in plastic roofing cement, covered with a fold of cotton saturated with asphalt or canvas, followed by a fold of 15-pound felt and another fold of cotton saturated with asphalt or canvas embedded in a bitumen. In addition, having no precise notion of the composition of the building such as the tightness of the vapor barrier, the insulation or the exact amount of air inlets; these elements do not allow us to give a guarantee on the final result. Proof of purchase showing the date, your name and the shipping address will be essential in order to make any warranty claim.